Three-phase asynchronous motor applications, but through the long after the operation, will be to produce all sorts of fault, timely judge fault reason, processed, it is to prevent failure expand, to ensure the normal operation of the equipment is an important work.
A, after electrify motor can't turn, but is ringing, and no smell and smoke.
1. The fault reason
(1) the power supply has been (at least two phase not tong);
(2) the melting silk fusing (at least two phase fusing);
(3) the flow relay the too small;
(4) control equipment wrong wiring.
2. Troubleshooting
(1) check the power supply circuit switch, melting silk, whether in the junction box a breakpoint, repair,;
(2) check melting model, fusing silk reason, change new investment silk;
(3) the set values and adjust relay motor cooperation;
(4) the correct wiring.
Second, after electrify motor not turn, and then melt silk burn off
1. The fault reason
(1) a photograph of power supply, or for a main circle opposite; the
(2) the stator winding alternate with short circuit;
(3) the stator winding grounding;
(4) the stator winding wiring error;
(5) a small section of the melt silk;
(5) the power cord short circuit or grounded.
2. Troubleshooting
(1) check whether there is a photograph not breaker together, can power supply circuit in a break; Eliminating reverse connect fault;
(2) the short-circuit point out to repair it;
(3) to eliminate grounding;
(4) found out by mistake, corrected;
(5) change melting silk;
(3) to eliminate take place.
Three, after electrify motor not turn with buzz
1. The fault reason
(1) the stator and the rotor winding there is open circuit (a phase break) or a power phase lose electric;
(2) lead wire winding beginning at the end of a faulty or winding at the internal;
(3) power supply circuit contacts, become loose, contact resistance;
(4) too big or rotor motor load stuck;
(5) the power supply voltage low;
6 small motors assembly is too tight or bearing grease in perfect;
7 bearing stuck.
2. Troubleshooting
(1) to find out breakpoint repair;
(2) check winding polarity; Judge winding end is correct;
(3) to tighten the screw loose connection, using a multimeter to judge whether the joint false meet to repair it;
(4) reducing load or find out and eliminate the machinery fault,
(5) is the rules also check the surface by law by mistake for Y; whether
Four, motor starting difficulties, rated load, motor speed below the rated speed more
1. The fault reason
(1) the power supply voltage low;
(2) the surface by law for the mistake by motor Y;
(3) of the rotor cage open welding or fault;
(4) the stator coil up, local at the wrong;
(3) to repair the motor winding circle number increase when too much;
(5) motor overloaded.
2. Troubleshooting
(1) the power supply voltage measurement, try to improve;
(2) the correct by law;
(3) check the welding and breakpoints and repair;
(4) found abrasive-cloth adhered by mistake, correct;
(5) restore correct circle number;
(6)and reducing load.
Five, the motor idle current imbalance, three-phase differ big
1. The fault reason (1) the heavy, stator three-phase winding circle number not equal; (2) the first pick the wrong end winding; (3) the power supply voltage is not balanced; (4) the winding.
after a news >> The importance of motor maintenance